China Flue gas heat exchanger Manufacturers Factory Suppliers
-
Flue Gas Heat Recovery UnitFlue Gas Inlet Temperature: 150–350℃read more
Flue Gas Outlet Temperature: 90–120℃
Heat Exchange Efficiency: 60%–80%
Flue Gas Resistance: ≤200 Pa
Material:... -
Air Compressor Waste Heat Recovery SystemFor oil-injected screw compressors, the heat recovery efficiency is over 60%.read more
Air channel resistance: < 2 kPa
Air inlet temperature: 100°C
Air flow rate: 20,000 m³/h
Working... -
Mine Water Source Heat Pump UnitSingle Unit Heating Capacity: 500kW – 2000kWread more
Heating COP: 4.0 – 6.0
Water Source Inlet Temperature: 10°C – 25°C
Heating Outlet Temperature: 45°C... -
Separated Heat Pipe Heat Recovery UnitExchange Efficiency: 55% - 70%read more
Evaporation Section Temperature: 50°C - 200°C
Condensation Section Temperature: 20°C - 80°C
Transport Distance: Horizontal ≤... -
Coal Mine Methane Heat Recovery DeviceExhaust Gas Recovery Efficiency: 70% – 85%read more
Exhaust Gas Inlet Temperature: 350°C – 550°C
Exhaust Gas Outlet Temperature: ≤120°C
Jacket Water Recovery... -
Mine Seepage Water Heat Recovery UnitSeepage Water Temp: 15–35℃ (Stable Year-round)read more
Water Treatment Capacity: 50–500 m³/h
Heat Pump COP: 4.0–5.5
Outlet Water Temp: 45–55℃
Pre-treatment: Filtration, Descaling,... -
Vertical Ground Loop Heat Pump SystemUnderground Soil Temp: 15–18℃ (Stable Year-round)read more
Heating COP: 4.0–5.0
Cooling EER: 3.5–4.5
Ground Loop Type: Vertical U-pipe (Single/Double U)... -
Gradient Waste Heat Recovery EquipmentRecovery Stages: 2–4 Level Gradient Utilizationread more
High-Temperature Stage (>150℃): Power Generation / Steam Production
Medium-Temperature Stage (80–150℃): Absorption Cooling... -
Mine Drainage Heat Recovery UnitDrainage Temperature: 18–30℃read more
Drainage Volume: 50–1000 m³/h
Recovery Efficiency: ≥70%
Heat Pump COP: 4.0–5.5
Outlet Water Temp: 45–55℃ -
Mine Vent Air Heat Recovery UnitExhaust Air Temperature: 15–25℃read more
Exhaust Air Volume: 100,000–500,000 m³/h
Heat Exchange Efficiency: 60%–75%
Fresh Air Temperature Rise: 8–15℃... -
Boiler Smoke Gas Thermal Recovery UnitFlue Gas Inlet Temperature: 180–250℃read more
Flue Gas Outlet Temperature: ≤90℃ (Condensing Type)
Recovery Efficiency: ≥90%
Boiler Efficiency Improvement: 5%–15%... -
Industrial Mine Heat PumpHeating COP: 3.5–4.5read more
Outlet Water Temperature: 80–85℃
Operation Method: Two-Stage Heat Pump Series System
Heat Source: Air Source + Water Source (Combined or...
Due to pollutants in the flue gases, this heat cannot be used directly for heating. To be able to use the flue gases nevertheless, a flue gas heat exchanger can...
Flue gas heat exchanger for steam boilers Effective heat recovery and reduction of flue gas losses Maximum efficiency gain when using condensing technology Fuel savings of up to 7%,...
Flue Gas Heat Exchanger - Murphy Thermal Energy Co. Flue gas heat exchanger helps in saving 1 of the boiler. The biggest advantage of it is that the metal wall temperature of the equipment...
A flue gas heat exchanger is part of the standard equipment for energy-optimised and environmentally friendly boiler operation. At a glance Effective heat recovery and reduction of...
Two (2) Flue gas / Water heat exchangers for industrial boilers. Systems are suitable for boiler capacities 20 ton/h and 22 ton/h. Flue gas is flowing outside the tubes in cross flow with the...
AFE flue gas Heat Exchangers can be used in a wide variety of sectors: for energy recovery in oil, gas or coal-fired power stations, in incineration plants and in general whenever acid dew...